Contents

Back to Steam Room and Steam Shower Section

 







Steam Generator Cautions:

1The generator should be installed where the water supply valve can be easily accessed for emergencies.
according to page 5.

2GFCI must be installed on the power supply, and the power supply, power wire, fuse and breaker must comply with the power and specification of the unit as shown in table 1 in this manual.

3The solenoid valve can endure maximum 0.2MPa (2kg/cm2) water pressure. To protect the solenoid valve from extremely high water pressure install a water pressure relieving valve if required.

4 Do not install saddle-backed or needle valves on the inlet. Please dredge and clean all installation pipework before connecting steam generator.

5 No block valve should be installed in the steam pipelines. Strictly no blocked or blended pipe, otherwise a negative effect on the flow of steam may occur. The steam pipelines should be installed with a slight angle so that the condensate can flow back to the generator or to the steam head.

6 Steam generator should be installed indoors and protected against the extreme cold. The generator should be installed and levelled with the arrow pointing upward at an easy-access place, otherwise do not switch on.


7 The steam pipeline must be in copper pipe, all other material such as plastic, acrylic should not be used as they cannot endure 150℃ or higher. Temperatures.

8 All inlet and apertures should be sealed to prevent any leakage of steam and to protect the generator and customers.

9 Draining water to the steam room from the water tank may cause serious scald and damage the steam room. A separate draining pipe is required to drain water to the drainage.